The Company
NorthMark Compute & Cloud (NMC²) is backed by dedicated leadership and investment, with a clear mission as it operates at the bleeding edge of technology. Its goal is to scale and enhance the high-performance computing (HPC) and cloud infrastructure that supports its clients' research, production, and delivery, enabling breakthroughs that shape the industries of tomorrow. Its engineers build critical infrastructure to eliminate friction in scientific research, simulations, analysis, and decision-making, accelerating discovery and driving faster innovation.
The Position
This role simulates and validates the structural integrity, airflow, and heat transfer of data center systems before they are built, using CFD, FEA, and transient thermal simulation to confirm multi megawatt server clusters will not overheat and that piping, structural, and turbine inlet systems can withstand real thermal, fluid, and seismic stresses. On self powered campuses with no utility grid backup, the same discipline extends to turbine inlet air and psychrometric assumptions used for capacity planning: this role validates design decisions from Structural, Mechanical, and Controls engineering against physics based modeling, and calibrates those models against real commissioning and site climate data so the digital prediction and the physical facility agree. This role reports to the Principal Engineer / Design Authority, Power and Cooling Systems.
Responsibilities
CFD Airflow and Thermal Modeling
- Build 3D CFD models of data halls to simulate airflow, velocity, and pressure drop; refine hot and cold aisle containment to eliminate hot spots and support the facility's PUE target
- Model exhaust plumes from cooling towers, chiller plants, and turbine equipment to confirm hot air is not recirculated into building air intakes
FEA Structural and Stress Analysis
- Use FEA to simulate piping, CDU, and heat exchanger expansion, contraction, and fatigue under sustained temperature cycling, and to analyze seismic loads on mechanical supports with Structural Engineering
- Simulate water hammer and pressure surges in liquid cooling loops to confirm piping and joints absorb mechanical shock without failure
Liquid Cooling and High Density AI Thermal Engineering
- Conduct micro scale thermal analysis on cold plates and microchannel heat exchangers for high wattage GPU/CPU chips; model immersion tank fluid convection, boiling behavior, and dielectric fluid performance
- Simulate liquid to liquid CDU approach temperatures and support technical evaluation of CDU, fan wall, and CRAH vendor submittals where design intent is in question
Turbine Inlet Air and Failure Scenario Modeling
- Model turbine inlet air chilling performance against site climate data, and reconcile manufacturer indicative capacity studies against ASHRAE design percentile data; flag any material gap in stated design humidity or dry bulb basis, since it directly affects inlet chilling sizing and available turbine capacity
- Run transient simulations for ride through time and single point failures (chiller, pump, row fan, turbine) to inform Controls fail safe design, with added weight given the reduced margin on a campus with no utility grid to fall back on
Validation and Model Calibration
- Partner with commissioning teams to gather real temperature, pressure, and airflow data during Level 4/5 testing, and calibrate FEA/CFD constraints so the digital twin matches actual facility behavior
- Maintain the portfolio's simulation model library so calibration data from one campus informs the analytical basis for the next
Gate and Milestone Accountability
- Gate 2, Concept: Preliminary CFD airflow, containment, and turbine inlet air/psychrometric modeling supporting the concept cooling and power approach.
- Gate 3, Design Freeze: FEA stress, ride through, and failure scenario simulations supporting FMEA and redundancy verification; no unresolved finding carried into the frozen IFC set.
- Gate 4, Commissioning Readiness: Empirical commissioning data compared against simulation predictions; material discrepancies flagged before live failover testing.
- Gate 5, Final Acceptance: Calibrated as built simulation models delivered as a validated digital twin for future capacity and failure planning.
Requirements
- BS in Mechanical Engineering, ABET accredited or equivalent, required; MS in Mechanical, Thermal/Fluids, or Computational Engineering strongly preferred
- PE license preferred, given this role's analytical support to engineer of record decisions made by other disciplines
- Proficiency with CFD software (ANSYS Fluent, Siemens STAR CCM+, 6SigmaDCX/Future Facilities) and FEA software (ANSYS Mechanical, Abaqus, or equivalent) required
- Formal training or experience in liquid cooling thermal physics (direct to chip, immersion, two phase) and working familiarity with psychrometrics and ASHRAE climate design data strongly preferred
- Data center CFD and thermal modeling: Typically 7 to 10 or more years of mechanical/thermal engineering experience, with hands on responsibility for data hall CFD and containment modeling, not solely general purpose CFD in an unrelated industry
- High density AI thermal physics: Experience in micro scale thermal analysis on cold plates, microchannel heat exchangers, or immersion cooling fluid dynamics
- FEA fluency: A track record using FEA to validate or challenge piping thermal expansion, seismic loading, and transient pressure design before it is built
- Failure scenario modeling: Experience running ride through and component failure simulations that directly inform FMEA and controls fail safe design, not academic exercises disconnected from decisions
- Model calibration discipline: Demonstrated experience comparing simulation predictions to commissioning data and adjusting model constraints, turning a simulation into a trustworthy digital twin
- Facility and cross functional fit: Data center, hyperscale, or high density computing thermal experience strongly preferred; experience on self powered or on site generation campuses is a plus. Able to translate results into guidance actionable by Structural, Piping, and Controls engineers who are not simulation specialists
It is impossible to list every requirement for, or responsibility of, any position. Similarly, we cannot identify all the skills a position may require since job responsibilities and the Company’s needs may change over time. Therefore, the above job description is not comprehensive or exhaustive. The Company reserves the right to adjust, add to or eliminate any aspect of the above description. The Company also retains the right to require all employees to undertake additional or different job responsibilities when necessary to meet business needs.
Must be legally authorized to work in the United States without the need for employer sponsorship, now or at any time in the future.
Benefits & Perks:
Company-Paid Lunch Stipend: Lunch is provided via GrubHub
Company-Paid Benefits: 100% Employer-Paid Medical in our High Deductible Health Plan, Dental and Vision benefits for employees and their families, 16 weeks of Paid Parental Leave, Employee Assistance Program, Life insurance, Short-Term Disability and Long-Term Disability
401(k): Company will match 100% of your contributions up to 6%
Optional Employee-Paid Benefits: Medical insurance in our PPO plan and a variety of other benefits such as Health Savings Accounts (with Company Contribution!), Flexible Spending Accounts, Supplemental Life Insurance, Wellhub and more.
Time Off: 25 days of Paid Time Off plus 12 company holidays
EQUAL OPPORTUNITY EMPLOYER
NORTHMARK STRATEGIES LLC IS AN EQUAL EMPLOYMENT OPPORTUNITY EMPLOYER. THE COMPANY'S POLICY IS NOT TO DISCRIMINATE AGAINST ANY APPLICANT OR EMPLOYEE BASED ON RACE, COLOR, RELIGION, NATIONAL ORIGIN, GENDER, AGE, SEXUAL ORIENTATION, GENDER IDENTITY OR EXPRESSION, MARITAL STATUS, MENTAL OR PHYSICAL DISABILITY, AND GENETIC INFORMATION, OR ANY OTHER BASIS PROTECTED BY APPLICABLE LAW. THE FIRM ALSO PROHIBITS HARASSMENT OF APPLICANTS OR EMPLOYEES BASED ON ANY OF THESE PROTECTED CATEGORIES.