The Company
NorthMark Compute & Cloud (NMC²) is backed by dedicated leadership and investment, with a clear mission as it operates at the bleeding edge of technology. Its goal is to scale and enhance the high-performance computing (HPC) and cloud infrastructure that supports its clients' research, production, and delivery, enabling breakthroughs that shape the industries of tomorrow. Its engineers build critical infrastructure to eliminate friction in scientific research, simulations, analysis, and decision-making, accelerating discovery and driving faster innovation.
The Position
Supports the Design Authority – SME on the power generation scope of new-construction data centers where gas turbines or reciprocating engines serve as the primary - not standby - source, operating islanded at an N+1 redundancy target. The EPC contractor designs, procures, and constructs; its lead engineer is Engineer of Record. This role reviews and independently verifies the contractor's engineering, performs owner-scope detailed engineering, supports construction and commissioning in the field, and prepares recommendations for the SME. The technical core of the role is islanded operation of dissimilar machines in parallel - load sharing, transient stability, and load shedding. This role reports to the Design Authority – SME.
Responsibilities
Design Review & Technical Verification
- Review and recommend disposition on contractor deliverables and vendor submittals: single-lines, load lists, short-circuit, load-flow, protective device coordination, arc-flash, EMT/transient studies, relay settings, cable ampacity, grounding, equipment specifications, and PMS/SCADA architecture
- Review load-sharing and governor/AVR philosophy for dissimilar machines in parallel - droop versus isochronous control, real and reactive power sharing, reactive droop compensation, and behavior on unit loss, load rejection, and re-synchronization
- Review islanded transient and dynamic stability studies, confirming machine, governor, and exciter models are vendor-validated for the units supplied rather than library defaults
- Review the IEC 61850 load-shedding and load-sharing implementation through the microgrid controller - GOOSE configuration, SCD/ICD/CID version control, message performance class, PRP/HSR redundancy, degraded modes - and confirm the assumed end-to-end shed time matches the margin relied on in the stability study
- Confirm coordination and arc-flash hold across all credible operating states (all units online, N-1, re-synchronization, black start, temporary power), that UL listings and code compliance are evidenced before procurement release, and that the FMEA demonstrates rather than asserts that loss of any single unit is absorbed without interrupting IT load
Detailed Engineering & Site Support
- Perform independent verification calculations and dynamic modeling in ETAP, and execute detailed engineering on owner-retained and owner-furnished scope, including interface and tie-in design and temporary power
- Provide field engineering support at construction tempo - RFIs, field change requests, proposed deviations - and attend witness and hold points per the approved ITPs
- Ensure field deviations return through the design review path rather than into the as-built. Monitor and report; means, methods, sequencing, and site safety remain the contractor's responsibility
Contractor Oversight & Change Management
- Administer the written-response protocol for owner technical objections, maintain the response-time ledger, and issue the owner's own minutes; originate technical queries and nonconformance reports and track each to verified closure; escalate hard-blocking safety, code, or cybersecurity items to the SME same business day
- Provide the technical determination distinguishing owner-directed scope change from design development from contractor rework; review change pricing on technical merit; and assemble the record supporting NMC2's commercial and claims positions
Commissioning, Testing & Acceptance
- Review commissioning plans, procedures, and pass/fail acceptance criteria before execution, and witness factory acceptance testing at the vendor's works
- Support site acceptance testing, protection and relay functional testing, energization, and integrated systems testing, including troubleshooting during startup
- Witness load-shedding and load-sharing functional testing - measured GOOSE and end-to-end shed timing against the study basis, controller failover, and dissimilar-machine load sharing under step load and unit loss
- Confirm the integrated systems test exercises N+1 failover under load and witness the live failover at handover; verify as-builts, O&M manuals, relay setting files, spares, and operator training; maintain the punchlist and recommend acceptance or that it be withheld
Requirements
- Education and licensure. BSEE from an ABET-accredited program, or equivalent international accreditation, is required. PE preferred, not required - the contractor's lead engineer is Engineer of Record and design authority rests with the SME. NFPA 70E and a commissioning credential (ACG, NEBB, or equivalent) preferred
- Prime generation depth. Typically 10+ years in electrical power systems, with hands-on experience on continuously-running paralleled generation as a primary power source - not solely standby/emergency experience per NFPA 110/111
- Power system analysis - required. Hands-on ETAP proficiency across load flow, short-circuit, motor starting, protective device coordination, arc-flash, and transient stability. Must be able to build and run studies personally, and to judge whether a contractor's dynamic study is properly constituted: correct machine and control models, vendor-validated governor and exciter parameters, and a credible contingency set
- Islanded operation of dissimilar generators in parallel - required. Direct experience where frequency and voltage are held by the machines on the bus, with paralleled units dissimilar in inertia, governor response, and load acceptance. Grid-parallel or grid-following experience alone does not meet this requirement
- IEC 61850 for load shedding and load sharing - required. GOOSE-based schemes through microgrid controllers - configuration, performance classes, network redundancy, and failure modes. Configuration review and site functional testing experience strongly preferred
- Generation packages and balance of plant - required. Intimate familiarity with gas turbine and reciprocating engine packages and their electrical and control interfaces, and with BOP auxiliary equipment including fuel gas compressors, heaters, pumps, and fans
- Standards and equipment - required. Fluent in ANSI, IEEE, and NEC. Working command of HV, MV, and LV switchgear, motor control centers, and transformers (GSU and step-down). GIS experience preferred
- Hands-on EPC execution experience - required. Time worked inside an EPC or design-build organization, with practical command of deliverable lifecycles, IFC release, submittal and RFI workflows, vendor data cycles, and turnover, plus demonstrated construction, startup, and commissioning time on active projects. Data center or mission-critical experience and documentary discipline preferred
It is impossible to list every requirement for, or responsibility of, any position. Similarly, we cannot identify all the skills a position may require since job responsibilities and the Company’s needs may change over time. Therefore, the above job description is not comprehensive or exhaustive. The Company reserves the right to adjust, add to or eliminate any aspect of the above description. The Company also retains the right to require all employees to undertake additional or different job responsibilities when necessary to meet business needs.
Must be legally authorized to work in the United States without the need for employer sponsorship, now or at any time in the future.
Benefits & Perks:
Company-Paid Lunch Stipend: Lunch is provided via GrubHub
Company-Paid Benefits: 100% Employer-Paid Medical in our High Deductible Health Plan, Dental and Vision benefits for employees and their families, 16 weeks of Paid Parental Leave, Employee Assistance Program, Life insurance, Short-Term Disability and Long-Term Disability
401(k): Company will match 100% of your contributions up to 6%
Optional Employee-Paid Benefits: Medical insurance in our PPO plan and a variety of other benefits such as Health Savings Accounts (with Company Contribution!), Flexible Spending Accounts, Supplemental Life Insurance, Wellhub and more.
Time Off: 25 days of Paid Time Off plus 12 company holidays
EQUAL OPPORTUNITY EMPLOYER
NORTHMARK STRATEGIES LLC IS AN EQUAL EMPLOYMENT OPPORTUNITY EMPLOYER. THE COMPANY'S POLICY IS NOT TO DISCRIMINATE AGAINST ANY APPLICANT OR EMPLOYEE BASED ON RACE, COLOR, RELIGION, NATIONAL ORIGIN, GENDER, AGE, SEXUAL ORIENTATION, GENDER IDENTITY OR EXPRESSION, MARITAL STATUS, MENTAL OR PHYSICAL DISABILITY, AND GENETIC INFORMATION, OR ANY OTHER BASIS PROTECTED BY APPLICABLE LAW. THE FIRM ALSO PROHIBITS HARASSMENT OF APPLICANTS OR EMPLOYEES BASED ON ANY OF THESE PROTECTED CATEGORIES.