The Berkshire Power Plant, located in Agawam, MA, is a 250-MW natural gas-fired combined-cycle facility featuring a single-shaft configuration. The plant utilizes an ALSTOM GT-24B gas turbine rated at 150 MW and an ALSTOM triple-pressure condensing steam turbine generating an additional 100 MW, coupled to a 340-MVA water- and air-cooled generator. Gas turbine exhaust passes through a dual-pressure reheat heat recovery steam generator (HRSG) operating at near-critical pressures.
Opportunity Summary
The Control Room Operator (CRO) at the Berkshire Power Plant oversees the safe and efficient operation of all plant systems, including monitoring, controlling, starting up, and shutting down equipment from the control room while ensuring compliance with regulatory and safety standards. This role requires a valid Second-Class Engineer License under the Commonwealth of Massachusetts License Law and involves managing plant logs, water chemistry, maintenance activities, and responding to alarms or upset conditions. The CRO also supports shift handovers, staff training, and continuous improvement initiatives to optimize plant performance.
Your scope of responsibility as CRO will include the following primary functions:
- Responsible for the overall operation of the power plant, including operating, monitoring, inspecting, and controlling all plant parameters from the control room.
- Maintain a valid MA Second-Class Engineer License under the Commonwealth of Massachusetts License Law, serving as the operator engineer in charge of the watch.
- Operate, monitor, start up, and shut down all plant equipment, including combustion turbines, HRSGs, steam turbines, generators, and auxiliary systems, ensuring safe and efficient performance.
- Oversee plant water chemistry and provide direction to maintain it within plant guidelines.
- Participate in daily preventive, scheduled, and repair maintenance activities in a safe, effective, and timely manner; assist with plant cleanup and housekeeping as directed.
- Ensure safe work practices, including lockout/tagout procedures, confined space entry, and hot work permits; supervise personnel and contractors to maintain compliance with safety standards.
- Actively participate in NAES Safety, Environmental, and Regulatory Compliance Programs, promoting a strong safety culture and adhering to all safety and environmental rules.
- Complete and maintain daily logs, plant and state logbooks, and other records documenting electrical and steam output, emissions, fuel and water consumption, heat rates, and operational activities accurately and timely.
- Enter work orders and other relevant data into the computerized maintenance management system (CMMS), maintain inventories, and perform other CMMS tasks as directed.
- Review logs, records, and operational data periodically to ensure effective procedures, identify trends, and recommend improvements to plant operation.
- Monitor plant equipment performance, respond to alarms, and report abnormalities to ensure timely corrective actions.
- Assist in managing plant upset conditions, including containment, control, and corrective actions as required.
- Conduct thorough and accurate shift handovers, briefing incoming personnel on plant issues and concerns.
- Assist in staff training and development initiatives to enhance operational competency.
- Execute tasks assigned by the Operations Manager, contributing to the plant’s operational success.
NAES Safe
Safety is a core value at NAES, and as a condition of employment, all employees are expected to remain mentally alert and work safely at all times. Employees must also adhere to all safety warnings and posted signs while on company property. Additionally, they are required to follow all NAES safety rules and procedures. Adherence to these safety responsibilities is one of the key factors in the evaluation of each employee’s performance.
Working Relationships
The CRO reports to the Operations Manager and responds to directions from other plant management. The CRO coordinates with all plant personnel as it pertains to the safe, efficient, and reliable operation of the facility.
Physical Requirements and Working Conditions
Physical requirements include standing for extended periods of time, climbing stairs and ladders, working from elevated platforms and walkways at varying heights, and routinely lifting up to 50 pounds.
Power plant environment that may involve entering confined spaces, crawling through narrow areas, and handling hazardous materials, with exposure to fumes, extreme temperatures, and noise. Work may include high heat near equipment and varying outdoor weather conditions.
Some duties may require the use of protective equipment, which can include hard hats, safety glasses, and eye protection, air masks/respirators, ear protection, chemical suits, flame-resistant clothing (FRC), hot gloves, high-voltage protective gear, and fall protection. Fit testing for respirators may be required. Strict smoking restrictions apply in and around the facility.
Fitness for Duty
All personnel will participate in the Fitness for Duty Program, which includes a post-offer physical examination, drug screening, and post-employment random drug screening.
Work Schedule
The CRO follows DuPont’s rotating 12-hour shift schedule, providing 24/7 coverage through a structured rotation of day and night shifts. This position will require extended hours, flexible shifts, weekends, and holidays as needed to support plant operations and business needs and may also require callout availability. Depending on the position, on-call status may or may not apply.
Compensation
This position offers a base pay rate ranging from $55 to $65.12 per hour, along with eligibility for an annual performance bonus.
Operational Experience and Core Qualifications
- An Associate degree in Power Plant Technology, Mechanical or Electrical Engineering Technology, Process Technology, or a related field is preferred. Equivalent technical training in industrial maintenance or instrumentation and control is beneficial but not required. Relevant industry or military experience may be considered in lieu of education.
- Must hold a valid Second-Class Engineer License in the Commonwealth of Massachusetts.
- Possession of a valid Grade One or higher Wastewater Operator License is preferred.
- Extensive experience in power plant operations, with a focus on control room management and system monitoring. Preferred experience in the direct operation of a combined cycle large frame gas turbine power plant.
- Strong understanding of plant equipment, systems, and operational procedures, including turbine generators, combustion turbines, and HRSGs.
- Theoretical and practical knowledge of combustion and steam turbine operations, closed system steam generation, electrical theory, controls application, industrial safety, hazardous waste management, and the inspection and recording of plant parameters.
- Experience in water chemistry control, analysis of water conditions, water treatment facility operations, and chemical handling requirements.
- Demonstrated leadership and supervisory experience, including the ability to direct and develop team members effectively.
- Proven track record of adhering to safety and environmental regulations, with the ability to enforce compliance among team members.
- Excellent verbal and written communication skills to effectively convey information to management and team members.
- Must possess a valid, unrestricted U.S. driver’s license and ensure it remains in good standing at all times.
About NAES
NAES Corporation is a leading provider of operations, maintenance, and engineering services for energy facilities. We serve clients across the power generation, oil and gas, and renewable energy sectors throughout North America and internationally, supporting the full life cycle of power generation and other industrial facilities.
NAES is committed to fostering a diverse and inclusive workplace. Employment decisions are based on merit and qualifications, without regard to race, color, religion, national origin, sex, gender identity, sexual orientation, age, disability, military status, USERRA-protected status, or any other characteristic protected by applicable federal, state, or local law.